Products XLPE INSTRUMENTATION CABLES INDIVIDUAL & OVERALL SCREENED SWA CABLES
CABLE APPLICATION
Description
Cable based on BS50288 requirements and any relevant AS/NZS requirements.
CABLE DESIGN
Conductor
Bare Annealed Copper to AS/NZS 1125
Core Colour
Each Pair one White and one Black Conductor with all pairs numbered
Insulation
Flame Retardant FR-V90 to UL Style 1596 and AS/NZS 3808
Screen
Individual Screens of Aluminium/Polyester Tape with a Tinned Copper 7/0.20 Drain Wire
Overall Screen is of Aluminum/Polyester Tape with a Tinned Copper 7/0.20 Drain Wire
Overall Screen is of Aluminum/Polyester Tape with a Tinned Copper 7/0.20 Drain Wire
Armoured
Steel Wire Armoured to AS/NZS 3863
Sheath
Black V-90 LSZH (low Smoke Zero Halogen) to UL Style 2464 & AS/NZS 3808
Inductance
0.5mm² - 1.10 mH/km@1khz
1.5mm² - 0.95 mH/Km@1khz
1.5mm² - 0.95 mH/Km@1khz
Capacitance
(Conductor to Conductor)
0.5mm² - 0.145 uf/km@1khz
1.5mm² - 0.20 uf/km@1khz
0.5mm² - 0.145 uf/km@1khz
1.5mm² - 0.20 uf/km@1khz
L/R Ratio
0.5mm² - 0.0157 mH/Ω
1.5mm² - 0.0365 mH/Ω
1.5mm² - 0.0365 mH/Ω
Flame Retardance
IEC60332-1
Note
1. These cables are not suitable for direct connection to mains supply.
2. Nominal voltage rating - AC/DC 110/150V
3. Not all sizes and colours are available ex-stock, minimum order quantity will apply for some items.
4. Special sheath colours on request.
5. Cables are Green Star / PVC best practice certified.
2. Nominal voltage rating - AC/DC 110/150V
3. Not all sizes and colours are available ex-stock, minimum order quantity will apply for some items.
4. Special sheath colours on request.
5. Cables are Green Star / PVC best practice certified.
0.5mm²
Part Number | Pairs | Cond. No./Dia. mm | Insulation Thickness mm | Overall Dia. Bedding | SWA Dia. | Overall Dia. Over Armour | Nom. Overall Dia. mm | Conductor resistance @20°C Ω/km | Approx. Mass Kg/100m |
---|---|---|---|---|---|---|---|---|---|
INS2P7030INDO/ALLSCRSWABK
|
2 | 7/0.30 | 0.4 | 8.3 | 0.9 | 10.1 | 11.5 | 38.4 | 31.8 |
INS4P7030INDO/ALLSCRSWABK
|
4 | 7/0.30 | 0.4 | 9.6 | 0.9 | 11.4 | 13.0 | 38.4 | 38.7 |
INS6P7030INDO/ALLSCRSWABK
|
6 | 7/0.30 | 0.4 | 11.4 | 0.9 | 13.2 | 15.0 | 38.4 | 48.0 |
INS8P7030INDO/ALLSCRSWABK
|
8 | 7/0.30 | 0.4 | 12.3 | 0.9 | 14.1 | 16.3 | 38.4 | 55.5 |
INS10P7030INDO/ALLSCRSWABK
|
10 | 7/0.30 | 0.4 | 14.4 | 0.9 | 16.2 | 18.6 | 38.4 | 65.1 |
INS12P7030INDO/ALLSCRSWABK
|
12 | 7/0.30 | 0.4 | 14.9 | 0.9 | 16.7 | 19.1 | 38.4 | 69.9 |
INS16P7030INDO/ALLSCRSWABK
|
16 | 7/0.30 | 0.4 | 16.6 | 0.9 | 18.4 | 21.2 | 38.4 | 99.5 |
INS20P7030INDO/ALLSCRSWABK
|
20 | 7/0.30 | 0.4 | 18.0 | 1.25 | 20.5 | 23.7 | 38.4 | 111.3 |
INS24P7030INDO/ALLSCRSWABK
|
24 | 7/0.30 | 0.4 | 20.6 | 1.25 | 23.1 | 26.5 | 38.4 | 127.7 |
INS36P7030INDO/ALLSCRSWABK
|
36 | 7/0.30 | 0.4 | 23.6 | 1.25 | 26.1 | 29.7 | 38.4 | 162.2 |
1.5mm²
Part Number | Pairs | Cond. No./Dia. mm | Insulation Thickness mm | Overall Dia. Bedding | SWA Dia. | Overall Dia. Over Armour | Nom. Overall Dia. mm | Conductor resistance @20°C Ω/km | Approx. Mass Kg/100m |
---|---|---|---|---|---|---|---|---|---|
INS2P7050INDO/ALLSCRSWABK
|
2 | 7/0.50 | 0.4 | 6.4 | 0.9 | 12.2 | 14.0 | 13.8 | 41.3 |
INS4P7050INDO/ALLSCRSWABK
|
4 | 7/0.50 | 0.4 | 12.1 | 0.9 | 13.9 | 16.1 | 13.8 | 53.2 |
INS6P7050INDO/ALLSCRSWABK
|
6 | 7/0.50 | 0.4 | 14.4 | 0.9 | 16.2 | 18.6 | 13.8 | 69.9 |
INS8P7050INDO/ALLSCRSWABK
|
8 | 7/0.50 | 0.4 | 15.7 | 0.9 | 17.5 | 20.3 | 13.8 | 80.5 |
INS10P7050INDO/ALLSCRSWABK
|
10 | 7/0.50 | 0.4 | 18.5 | 1.25 | 21.0 | 23.8 | 13.8 | 113.6 |
INS12P7050INDO/ALLSCRSWABK
|
12 | 7/0.50 | 0.4 | 19.2 | 1.25 | 21.7 | 24.9 | 13.8 | 125.2 |
INS16P7050INDO/ALLSCRSWABK
|
16 | 7/0.50 | 0.4 | 21.4 | 1.25 | 23.9 | 27.1 | 13.8 | 147.7 |
INS20P7050INDO/ALLSCRSWABK
|
20 | 7/0.50 | 0.4 | 23.3 | 1.25 | 25.8 | 29.2 | 13.8 | 171.8 |
INS24P7050INDO/ALLSCRSWABK
|
24 | 7/0.50 | 0.4 | 26.7 | 1.60 | 29.9 | 33.5 | 13.8 | 223.6 |
INS36P7050INDO/ALLSCRSWABK
|
36 | 7/0.50 | 0.4 | 31.2 | 1.60 | 34.4 | 38.2 | 13.8 | 286.4 |