Multipair Overall Aluminium Foil and Tinned Copper Braid Screen

Need help choosing the right product?

Our team is here to help.

Cable Design

Use:

Low capacitance RS232, RS422 applications.

Insulation: Polypropylene or Polyethylene as in indicated.
Sheath: Standard Grey V75 PVC. Other materials and colour on request.
Screen: Overall Aluminium/Polyester Laminate and TInned Copper Wire screens with Stranded Tinned Copper Drain Wire, between the screens.
Colour: As per Section B, Multipair Cables in the CMI Cable Catalogue.
Note:

These cables are not suitable for direct connection to mains supply.

Table 1

Installation Speaker Cable

Part Number Nearest AWG No. Of Pairs Cond. No./Dia. mm Insulation Thickness mm Nom. Capacitance Nom. Dia. mm
K6102 24 2 7/0.20 TC 0.3 50 pf/m 6.1
K6103 24 3 7/0.20 TC 0.3 50 pf/m 7.5
K6104 24 4 7/0.20 TC 0.3 50 pf/m 8.2
K6106 24 6 7/0.20 TC 0.3 50 pf/m 9.0
K6108 24 8 7/0.20 TC 0.3 50 pf/m 10.9
K6110 24 10 7/0.20 TC 0.3 50 pf/m 11.2
K6112 24 12 7/0.20 TC 0.3 50 pf/m 11.3
K6116 24 16 7/0.20 TC 0.3 50 pf/m 13.0
K6120 24 20 7/0.20 TC 0.3 50 pf/m 14.5
K6125 24 25 7/0.20 TC 0.3 50 pf/m 15.2
*Capacitance between conductors of a pair.